On a server with two or more network interfaces, iscsiadm -m discovery can hang and then fail with a timeout, although the storage answers on one of the interfaces. The two usual causes are that the kernel sends the request out of the wrong interface, and that reverse path filtering drops the replies when several interfaces are in the same subnet. The fix is to bind iSCSI to specific interfaces and, if needed, relax the filter.

1. Check the path to the storage

ip route get 10.10.10.50
ping -c 3 -I eth1 10.10.10.50

The first command shows which interface the kernel would use to reach the storage portal; the second tests one interface explicitly.

2. Bind iSCSI to the storage interfaces

Create one iSCSI interface record per network interface that should carry storage traffic:

iscsiadm -m iface -I iface-eth1 --op=new
iscsiadm -m iface -I iface-eth1 --op=update -n iface.net_ifacename -v eth1
iscsiadm -m iface -I iface-eth2 --op=new
iscsiadm -m iface -I iface-eth2 --op=update -n iface.net_ifacename -v eth2

Then discover and log in through those interfaces:

iscsiadm -m discovery -t sendtargets -p 10.10.10.50 -I iface-eth1 -I iface-eth2
iscsiadm -m node -l

With two bound interfaces you get two sessions per target, which multipath combines into one device (see how to scan for new LUNs with multipath).

3. Interfaces in the same subnet: reverse path filtering

If both storage interfaces have addresses in the same subnet, strict reverse path filtering (rp_filter = 1) can drop replies arriving on the "other" interface. Switch the storage interfaces to loose mode:

cat > /etc/sysctl.d/90-iscsi-rpfilter.conf <<'EOF'
net.ipv4.conf.eth1.rp_filter = 2
net.ipv4.conf.eth2.rp_filter = 2
EOF
sysctl --system

Separate subnets per storage path avoid this problem altogether and are the common design for iSCSI multipath.

4. Shorter timeouts for unreachable portals

If some listed portals are not reachable from this server, discovery waits for each. The login timeout can be lowered in /etc/iscsi/iscsid.conf with node.conn[0].timeo.login_timeout (default 15 seconds); restart iscsid afterwards.

Official documentation: Configuring an iSCSI initiator (Red Hat) and open-iscsi.

Related services

KVM VPS hosting

NVMe SSD and full root access, with Free Basic Managed Support.

Unmanaged dedicated servers

full root access and free IPMI KVM, with Free Basic Managed Support.

Linux server management

hardening, patching, monitoring and automation for Ubuntu, Debian, RHEL and AlmaLinux.

Was this answer helpful?

Still stuck? Open a ticket